How do I change how often the Knowledge Consistency Checker runs?
The Knowledge Consistency Checker (KCC), which manages connection objects for
inter- and intrasite replication, runs every 15 minutes by default. To change
this time period, start regedit and go to the
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\NTDS\Parameters Registry
entry.
From the Edit menu, select New, DWORD Value. Enter
Repl topology update period (secs)
and press Enter. Double-click the new value, and enter the number of seconds for
how often you want the KCC to run. Click OK, then close the Registry editor.
Restart the machine for the change to take effect
Security FAQ
Windows Privacy Tools - http//www.privacywindows.com
|